As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C CABIN FLOOR SUPPORT OTBD ATT SPLICE ANGLE FOUND CRACK JUST AT STA 1578 LBL 76 INCH CRACK LENGTH 0.75 INCH. BULK CARGO STA 1578 LBL 76 INCH FLOOR SUPPORT OTBD ATTACH SPLICE ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 45.