What was found
INSPECTION TYPE:C CABIN FLOOR SUPPORT INBD ATT SPLICE ANGLE FOUND CRACK JUST AT STA 1578 LBL 75 INCH CRACK LENGTH 1.75 INCH. BULK CARGO STA 1578 LBL 75 INCH FLOOR SUPPORT INBD ATTACH SPLICE ANGLE REPLACED AND INSTALLED AS PER SRM 51-10-02 AND 51-40-02 REV 45.