What was found
INSPECTION TYPE:SV SURVEY SEQ 752-W4-05 REPAIR RT WING LEADING LOWER SURFACE AT STA XFS 310 HAS FASTENER SPACING LESS THAN 4D & TRACK EXTENDS THROUGH PREVIOUS STOP DRILLED HOLE. REPAIRED PER TIMCO REO-G12591 AND EO DC8-5720-32212.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV SURVEY SEQ 752-W4-05 REPAIR RT WING LEADING LOWER SURFACE AT STA XFS 310 HAS FASTENER SPACING LESS THAN 4D & TRACK EXTENDS THROUGH PREVIOUS STOP DRILLED HOLE. REPAIRED PER TIMCO REO-G12591 AND EO DC8-5720-32212.