What was found
INSPECTION TYPE:SV SS 572-F1-48, "D" CARGO PIT DOOR EXT SURFACE STA 1414-1426, L28R, REPAIR CONFIGURATION DOES NOT CORRELATE TO A SRM (STAINLESS DOUBLER INSTALLED). REPAIRED PER DC SRM 52-2-0 FIG 2 SHT 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV SS 572-F1-48, "D" CARGO PIT DOOR EXT SURFACE STA 1414-1426, L28R, REPAIR CONFIGURATION DOES NOT CORRELATE TO A SRM (STAINLESS DOUBLER INSTALLED). REPAIRED PER DC SRM 52-2-0 FIG 2 SHT 3.