What was found
INSPECTION TYPE:SV EXT FUSELAGE, EXISTING FLUSH REPAIR AT STA 514-510 L35L, FASTENER SPACING LESS THAN 4D MINIMUM - MEASURED MINIMUM 2 PLACES TO BE .625 INCH. FABRICATED REPAIR DOUBLER AND FINGER DOUBLERS IAW DC8 SRM 53-02-01 PG 1 FIG 7 SHEETS 3, 23, 24. INSTALLED REPAIR IAW DC8 SRM 53-02-01-00 FIG 7, SHEET 23.