What was found
INSPECTION TYPE:SV SURVEY SEQ 814-F1-18 EXT FUSELAGE DOUBLER AT BS 165 TO BS 143 L13R HAS 6EA FASTENERS EDGE DISTANCE LESS THAN 1.5 FASTENER DIAMETER. REPAIR ACCOMPLISHED PER RE0-G12670 REV A AND UPS EO DC8-5320-32844-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV SURVEY SEQ 814-F1-18 EXT FUSELAGE DOUBLER AT BS 165 TO BS 143 L13R HAS 6EA FASTENERS EDGE DISTANCE LESS THAN 1.5 FASTENER DIAMETER. REPAIR ACCOMPLISHED PER RE0-G12670 REV A AND UPS EO DC8-5320-32844-A.