What was found
INSPECTION TYPE:SV VALIDATE REPAIR EFN 71819941057, ORIGINAL NON-ROUTINE 196958, LOCATION RT WING L/E XFS 188. WHEN INTERIM REPAIR WAS C/W, STEP 2A NR 30, STOP DRILL DAMAGED INTERCOSTAL STRUCTURE, INTERIM REPAIR C/W BEFORE A/C ARRIVAL AT DHC. REPAIRED PER TIMCO REO-G12815 REV A, AND UPS EO DC8-5730-33658-A.