What was found
INSPECTION TYPE:4C REPAIR SURVEY SEQ W4-004, RT WING NR 2 SLAT, SUPPORT ANGLE HAS AN EXISTING REPAIR, BASE STRUCTURE IS .050 INCH, PER SRM 57-00-01 FIG 3 REQUIRES STACKED ANGLE (2) NOT ON MRCSSR. REMOVED EXISTING REPAIR ANGLE, FABRICATED AND INSTALLED 2 EA ANGLES IAW UPS EO MD11-5740-32539-A.