What was found
INSPECTION TYPE:C REPAIR SURVEY SEQUENCE NR 259-S2-001 RT HORZ STAB O/B ELEVATOR AFT O/B EDGE NEEDS REPAIRS VALIDATION. BASE UPON EO MD11-5100-30530-B SEQ 259-S2-001, REPAIR DOES NOT CORRELATE WITH MD11 SRM 51-61-01 VOL II, REV 40 & NO. MRCSSR ISSUED. EARN RAISED. EXISTING REPAIR DOUBLER REMOVED. RT HORZ STAB O/B ELEVATOR AFT O/B EDGE REPAIRED IAW EARN: N259UP-0021. HOLES PICKED-UP & FASTENERS INSTALLED. PAINT TOUCHED UP ON REWORKED AREA PER SRM 51-21-02 VI, R40.