INSPECTION TYPE:C LOWER CTR CARGO COMPT BILGE AREA BETWEEN STA 5-113 AND STA 1541, LONGER ON 50R, LONGERON SPLICE FITTING FOUND WITH CRACKED AS MARKED. EXISTING CRACKED SPLICE REMOVED, 1 EA NEW SPLICE P/N A5A7114-515 HOLES PICK-UP. NEW HOLES ON SPLICE REPROTECTED. NEW SPLICE PAINTED & INSTALLED AS PER DRAWING N5A6774 AND EN 1175-09.