What was found
INSPECTION TYPE:C CENTER WING TANK UPPER SKIN EXT SURFACE LT SIDE STA 1226.5 STRINGER 15 XCW +78 FOUND FUEL SEEPING UNDER DOUBLER. EXISTING DOUBLER REMOVED, 1 EA HOLE REAMED TO 0.309 INCH PER EN1144-09. FPI C/O AFFECTED AREA, FOUND NO CRACK EVDNT. OPEN HOLE HFEC INSP C/O ON REMOVED FASTENER HOLES & FOUND NO CRACK EVDNT.0.309 INCH HOLE TRIM OFF HFEC INSP C/O ON TRIM OFF AREA, FOUND NO CRACK EVDNT. REPAIR DOUBLER & FILLER FABRICATED. REPAIR PARTS INSTALLED AS PER EN1144-09.