What was found
INSPECTION TYPE:C LT WING L/E LOWER ACCESS NR 519CB COMPT FOUND BEADED DOUBLER CRACKED AS MARKED, STA XORS 536 APPROX. DAMAGE AREA AT BEADED DOUBLER TRIM OFF PER SRM 57-10-00, FIG 27, VOL I, REV 40. HFEC INSP C/O ON TRIMMED OUT EDGE AND FOUND NO CRACK EVIDENT. REPAIR ANGLES, REPAIR FILLER AND REPAIR DOUBLER FABRICATED PER SRM 57-10-00 FIG 27, VOL I, REV 40. REPAIR PARTS HOLES PICKED-UP, PROTECTED AND PAINTED. REPAIR PARTS INSTALLED PER SRM 57-10-00 FIG 27, VOL I, REV 40.