What was found
INSPECTION TYPE:2C DEFERRED ITEM D-394892: MAIN DECK FLOORBEAM LWR FLANGE DENT FS 939, ALSO HFEC REINSP. REMOVED TEMP REPAIR, FABRICATED AND INSTALLED REPAIR FILLER AND ANGLE IAW SAA EA 011-5310-01-A1884 AND IPXA EO MD11-5310-32323-B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2C DEFERRED ITEM D-394892: MAIN DECK FLOORBEAM LWR FLANGE DENT FS 939, ALSO HFEC REINSP. REMOVED TEMP REPAIR, FABRICATED AND INSTALLED REPAIR FILLER AND ANGLE IAW SAA EA 011-5310-01-A1884 AND IPXA EO MD11-5310-32323-B.