What was found
INSPECTION TYPE:2C DURING OK TO INSTALL LT I/B FLAP T/E WEDGE, FOUND T/E CORNER DAMAGED 74 INCHES I/B FROM O/B END. REMOVED DAMAGE, INSTALLED FIBERGLASS DOUBLER IAW MD-11 SRM 57-50-02 REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2C DURING OK TO INSTALL LT I/B FLAP T/E WEDGE, FOUND T/E CORNER DAMAGED 74 INCHES I/B FROM O/B END. REMOVED DAMAGE, INSTALLED FIBERGLASS DOUBLER IAW MD-11 SRM 57-50-02 REPAIR 2.