What was found
INSPECTION TYPE:4C, DENT ON LOWER SURFACE OF RT INBD FLAP LOWER SURFACE, 13.25" FROM DENT TO OTBD FLAP HINGE FAIRING AND 41.5" FROM DENT TO T/E. CUT OUT DAMAGED AREA ON RT INBD FLAP LOWER SKIN BETWEEN STA XIFH 249-2 55. FABRICATED 1EA EXTERNAL DOUBLER AND INSTALLED REF EO MD11- 5750-01-A2801 AND STA, SA, EA 011-5750-01-A2801.