What was found
INSPECTION TYPE:4/C, PREVIOUS DAMAGE REPAIR TO BULK CARGO FLOORBOARD 161GF 46" FWS OF REAR WALL SHELF RBL 32 NOT IAW SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:4/C, PREVIOUS DAMAGE REPAIR TO BULK CARGO FLOORBOARD 161GF 46" FWS OF REAR WALL SHELF RBL 32 NOT IAW SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-D, APPX. D.