As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHEN OPENING MAIN ENTRY DOOR, TESTED SLIDE WARNING AND OBSERVED ORAL WARNING BUT NO FLASHING RED LIGHT. FOUND MINOR CORROSION ON CONNECTOR PLUG AT AUTONOMOUS POWER SUPPLY IAW ASM 52-73-00. CLEANED AND RESEAT CONNECTOR AND OPS CHECK IAW MM 52-73-14-04. OPS CHECK NORMAL.