As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEAVING FL350 GOT GREEN HYD LOW RES QTY WARNING. DID AOM PROC THEN NOTICED QTY ABOVE RED DOT SAME. TURNED PUMPS BACK ON AND LOWERED GEAR--QTY WENT BACK INTO GREEN BAND. LEFT PUMPS ON FOR DURATION OF FLIGHT. EMERGENCY DECLARED. LANDING UNEVENTFUL. T/S IAW MM 29-00-00-03. INSP. OF GREEN HYD SYS. IF PUMP OPERATES WITH LOW AIR PRESSURE OR LOW LEVEL. FOUND NR 1 ENG EDP LEAKING. R & R NR1 ENG PUMP IAW MM 29-11-32-04.