What was found
INSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL 231KG HAS PAINT EROSION TO SUBSTRATE AND IS DELAMINATED. FABRICATED NEW MAIN DECK FLOOR PANEL 231KG IAW EO A300-5320-16407-D APPENDIX A/B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL 231KG HAS PAINT EROSION TO SUBSTRATE AND IS DELAMINATED. FABRICATED NEW MAIN DECK FLOOR PANEL 231KG IAW EO A300-5320-16407-D APPENDIX A/B.