What was found
INSPECTION TYPE:5YR, DEFERRED ITEM D-427059 BULK CARGO FLOOR HAS 2.5 IN DIA HOLE 12 IN AFT OF CARGO DOOR CUTOUT AND 16 IN INBD OF CUTOUT. FABRICATED NEW BULK CARGO FLOOR PANEL 162HF IAW EO A300-5320-16407-D APPENDIX A/D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:5YR, DEFERRED ITEM D-427059 BULK CARGO FLOOR HAS 2.5 IN DIA HOLE 12 IN AFT OF CARGO DOOR CUTOUT AND 16 IN INBD OF CUTOUT. FABRICATED NEW BULK CARGO FLOOR PANEL 162HF IAW EO A300-5320-16407-D APPENDIX A/D.