What was found
INSPECTION TYPE:C1, NR 6 SLAT HAS "OUT OF LIMITS" DENTS LOCATED ON UPPER T/E WEDGE AT 8.5" FROM INBD 7.5" FROM T/E. NR 6 SLAT T/E WEDGE WAS REPAIRED IAW SRM 53-43-02-2R-1.