INSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 483 RBL 10 WL 208 INTERCOSTAL UPPER FLANGE IS DAMAGED AT THE FASTENER HOLE. REMOVED AND REPLACED THE (CHORD) INTERCOSTAL IAW SRM 51-40-05, 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, MAIN CARGO BAY INTERIOR BS 483 RBL 10 WL 208 INTERCOSTAL UPPER FLANGE IS DAMAGED AT THE FASTENER HOLE. REMOVED AND REPLACED THE (CHORD) INTERCOSTAL IAW SRM 51-40-05, 51-40-02.