What was found
INSPECTION TYPE:C2 LT HORIZONTAL STABILIZER UPPER SURFACE IS DENTED 40 INCHES FROM INBD, 14 INCHES FR FROM L/E. REPAIRED LT HORIZONTAL STABILIZER UPPER SURFACE 40 INCHES FROM INBD, 14 INCHES FROM L/E IAW SRM 51-70-10-2R-4 REPAIR 4 AND SRM 51-70-10-2R REPAIR GENERAL.