What was found
INSPECTION TYPE:C4, BS 880 TO BS 900, RBL 25 TO 45 FLOORBOARD IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C4, BS 880 TO BS 900, RBL 25 TO 45 FLOORBOARD IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.