What was found
INSPECTION TYPE:C4, BS 340-440 RBL 0.25 WL 208 FLOORBOARD IS DAMAGED ON EDGE FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C4, BS 340-440 RBL 0.25 WL 208 FLOORBOARD IS DAMAGED ON EDGE FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.