INSPECTION TYPE:C4, FUSELAGE FLOOR STRUCTURE, SEAT TRACK HAS CORRODED NUTPLATES AT RBL 60 INBD FLANGE AT STA 1185 TO STA 930. R & R SEAT TRACK IAW SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 53-00-52-1A1, SRM 51-40-05-0G, SRM 51-40-08, DWG 144N5016