What was found
INSPECTION TYPE:C4 FIBER GLASS DELAMINATED FROM MILLED AREA ON MAIN CARGO BAY FLOOR PANEL LOWER SURFACE BS 440 TO 480 RBL 45-60. REPLACED PER SRM 53-00-50-1A1 AND UPS EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C4 FIBER GLASS DELAMINATED FROM MILLED AREA ON MAIN CARGO BAY FLOOR PANEL LOWER SURFACE BS 440 TO 480 RBL 45-60. REPLACED PER SRM 53-00-50-1A1 AND UPS EO B757-5320-9692-G.