What was found
INSPECTION TYPE:C1 MECHANICAL DAMAGE ON ACCESS PANEL, BS 508, 8" ABOVE FLOOR LEVEL INSIDE MAIN CARGO DOOR. REMOVED DAMAGED AREA, FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT PANEL IAW SRM 52-30-02-1A1 FIGURE 101, SRM 52-30-02 DETAIL IV, SRM 51-40-05-0G, SRM 51-40-02-0G