What was found
INSPECTION TYPE:C1, SCREW STRIKE ON INBD FLANGE OF B/S 1200 FRAME BETWEEN 15L AND 16L. DAMAGED FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED BY DRILLING TO .128 HOLE. INSTALLED FASTENER IAW SRM 53-00-07-1A1 AND EO B757-5310-19952.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, SCREW STRIKE ON INBD FLANGE OF B/S 1200 FRAME BETWEEN 15L AND 16L. DAMAGED FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED BY DRILLING TO .128 HOLE. INSTALLED FASTENER IAW SRM 53-00-07-1A1 AND EO B757-5310-19952.