What was found
INSPECTION TYPE:C1, DRILL START DAMAGE ON FRAME AT BS 660 BETWEEN STRINGER 15R AND 16R. FOUND 2EA DAMAGED AREAS TO BE OUT OF LIMITS. REMOVED DAMAGED BY DRILLING .098 HOLE AT UPPER AND .194 HOLE AT LOWER. INSTALLED 2EA RIVETS IAW SRM 53-00-07-1A1, SRM 51-20-01-0G, EO B757-5310-19952.