What was found
INSPECTION TYPE:C4, BULK CARGO BAY; FLOOR PANEL SUPPORT HAS 2 EA CORRODED NUTPLATES, STA 1469, AND 1470, LBL 16. 10. REMOVE NUTPLATES; REMOVED CORROSION FROM SUPPORT. FOUND TO BE OUT OF LIMITS, ORDERED AND RECEIVED NEW FLOOR SUPPORT LOCATED AND INSTALLED IAW SRM 51-40-02-06, SRM 51-40-05-0G. SRM 51-40-08-0G.