What was found
INSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1320 THRU 1420 LBL 25 THRU LBL 45 HAS AN INSERT PULLING THROUGH AND SEVERAL DENTS AND GOUGES ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL AT BS 1320 THRU 1420 LBL 25 THRU LBL 45 HAS AN INSERT PULLING THROUGH AND SEVERAL DENTS AND GOUGES ON LOWER SURFACE. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.