What was found
INSPECTION TYPE:C3, 44 SECTION, CORROSION ON FLOOR SUPPORT AT STA 1055 LBL 28 FWD FLANGE. REMOVED AND REPLACED FLOOR SUPPORT B/S 1055 LBL 28 IAW SRM 51-40-02, SRM 51-40-05, AND DWG 144N5080.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, 44 SECTION, CORROSION ON FLOOR SUPPORT AT STA 1055 LBL 28 FWD FLANGE. REMOVED AND REPLACED FLOOR SUPPORT B/S 1055 LBL 28 IAW SRM 51-40-02, SRM 51-40-05, AND DWG 144N5080.