What was found
INSPECTION TYPE:C3, WHILE ACCESSING NUTPLATES, FOUND SUPPORT STIFFENER AT BS 1716, WL 207, FROM RBL TO RBL 25 IS CORRODED. REMOVED, FABRICATED, AND INSTALLED NEW SUPPORT STIFFENER IAW DWG NR 146N5240, SRM 53-00-51-1A 1, SRM 51-10-02-OG, SRM 51-40-02.