What was found
INSPECTION TYPE:C3, FLOOR SUPPORT AT BS 652, RBL 10.45 HAS CORROSION ON THE UPPER SURFACE. REMOVED CORROSION ON FLOOR SUPPORT AT BS652, RBL10.45 IN AREA OF 2.5"X1"X.010 ORIGINAL THICKNESS .063 FOUND TO BE OUT LIMITS IAW SRM 53-30-53-01 DETAIL. R & R FLOOR SUPPORT FROM BS633 TO 705 R BL10.45 WL156.5 IAW SRM 51-40-02.