What was found
INSPECTION TYPE:C3, RT FLOOR TO SIDEWALL PUNCTURED BS 1475.5. REPAIRED RT FLOOR TO SIDEWALL SRM 53-00-53-1A 1. DWG 146N5390, SRM 51-40-01-00, SRM 51-70-11-OG, AMM 25-57-01-4, AMM 25-50-02-4, AMM 25-50-04-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, RT FLOOR TO SIDEWALL PUNCTURED BS 1475.5. REPAIRED RT FLOOR TO SIDEWALL SRM 53-00-53-1A 1. DWG 146N5390, SRM 51-40-01-00, SRM 51-70-11-OG, AMM 25-57-01-4, AMM 25-50-02-4, AMM 25-50-04-4.