As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C3, 43 SECTION FLOORBOARD AT STA 480 TO STA 560, LBL 45 TO LBL 61 INBD EDGE DISBONDED AND 2 INSERTS MISSING FROM FWD EDGE. MADE REPLACEMENT FLOOR PANEL USING OLD PANEL AS A TEMPLATE USING MATERIAL A402H LOT NR 921330 IAW EO NR B757-5320-9692.