INSPECTION TYPE:C2, NR 4 SLAT HAS OUT OF LIMIT DENTS (DUE TO CLOSE PROXIMITY) LOCATED ON T/E WEDGE UPPER SURFACE 45" FROM INBD END 2.25" FROM T/E. REPAIRED NR 4 SLAT T/E WEDGE IAW SRM 51-70-10-2R-4 AND SRM 51-70-10-2R-0.