What was found
INSPECTION TYPE:C2, MCB FLOOR PANEL HAS PUNCTURED DAMAGE AND DELAMINATED AREAS BS 820 TO 879, LBL 45 TO LBL 60, WL 208. FABRICATED FLOOR PANEL FROM A402H TEKLAN IAW EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, MCB FLOOR PANEL HAS PUNCTURED DAMAGE AND DELAMINATED AREAS BS 820 TO 879, LBL 45 TO LBL 60, WL 208. FABRICATED FLOOR PANEL FROM A402H TEKLAN IAW EO B757-5320-9692-G.