What was found
INSPECTION TYPE:C2, MCB FLOOR SUPPORT IS DENTED ON AFT SIDE WITH PLATE CORRODED AT BS 1016 BETWEEN RBL 25-45 WL 208. REPLACED IAW SRM 51-40-08. 51-40-05, DWG 144N5003.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, MCB FLOOR SUPPORT IS DENTED ON AFT SIDE WITH PLATE CORRODED AT BS 1016 BETWEEN RBL 25-45 WL 208. REPLACED IAW SRM 51-40-08. 51-40-05, DWG 144N5003.