What was found
INSPECTION TYPE:C2, FWD CARGO RT FLOOR TO SIDEWALL SUPPORT UPR SURFACE HAS 3 EA GOUGES BS 794.5-796.5, RBL 21. GOUGED AREAS FOUND TO BE OUT OF LIMITS, REPLACED IAW SRM 53-30-53-011 AND SRM 53-00-53-1A, SRM 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, FWD CARGO RT FLOOR TO SIDEWALL SUPPORT UPR SURFACE HAS 3 EA GOUGES BS 794.5-796.5, RBL 21. GOUGED AREAS FOUND TO BE OUT OF LIMITS, REPLACED IAW SRM 53-30-53-011 AND SRM 53-00-53-1A, SRM 51-40-02-0G.