What was found
INSPECTION TYPE:C2, RT SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS OF SURFACE CORROSION AT NUTPLATE LOCATIONS, BS 1530 TO BS 1640, RBL 20 TO RBL 25, (APPROX WL 145). REPLACED SIDE PANEL ASSY IAW SRM 53-00-53-1A1, SRM 53-60-53-0I1, SRM 51-40-02.