What was found
INSPECTION TYPE:C2, BS 395 STR CLIP AT STR 4L GOUGED ALONG OTBD EDGE. R & R STRINGER CLIP IAW SRM 51-10-02-0G, SRM 51-40-02-0G, AND DWG 141N0500.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, BS 395 STR CLIP AT STR 4L GOUGED ALONG OTBD EDGE. R & R STRINGER CLIP IAW SRM 51-10-02-0G, SRM 51-40-02-0G, AND DWG 141N0500.