INSP TYPE:C3 LATERAL FLOORBEAM UPPER CHORD UPPER SURFACE IS CORRODED IN SEVERAL AREAS AT BS 879 BETWEEN RBL 29-41, WL 208. REPAIRED IAW ER 10-4318.