What was found
FX - SURVEY SEQUENCE NR 314-F1-04 STA382 TO 398 BETWEEN STR33L TO 35L THE EXISTING REPAIR NOT CORRELATE TO SRM DUE TOO CLOSE OF 314-F1-03 EXISTING REPAIR DOUBLER. FX SURVEY SEQUENCE NR 314-F1-04 STA382 TO 398 BTN STR33L-35L SKIN REPAIRED IAW RS R53-11-36575 ORG MATL & THICNESS ARE CLAD2024T3 CHEM-MILLED SKIN 0.056" AT EXISTING CUTOUT WITH SIZE 1" X 3.75" THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR. REPAIR SIZE IS 14" X 8" FOLLOW UP ACTION IS REQUIRED REFER EO B767-5330-36226-A.