INSPECTION TYPE:C, BULK CARGO COMPT STA 1415 LBL 8" FLOOR PANEL SUPPORT (DEPRESSOR) LOWER RIVET AREA FOUND CRACK. FLOOR PANEL SUPPORT REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02, REV 46.