What was found
INSPECTION TYPE:C, MAIN DECK COMPT STA 1581 RBL 70" FLOOR PANEL SUPPORT INBD ANGLE FOUND CRACKED. MAIN DECK COMPT STA1581 RBL70" FLOOR PANEL SUPPORT INBD ANGLE REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MAIN DECK COMPT STA 1581 RBL 70" FLOOR PANEL SUPPORT INBD ANGLE FOUND CRACKED. MAIN DECK COMPT STA1581 RBL70" FLOOR PANEL SUPPORT INBD ANGLE REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 46.