What was found
INSPECTION TYPE:6C, LT WING - INBD MAIN FLAP INBD HINGE FTG FOUND CRACKED. LT WING - INBD MAIN FLAP HINGE FTG, REPAIRED IAW SRM 57-53-02-2R1, FIG 201, REF 46, ORIGINAL MATERIAL IS 7075T73 FORGING, CRACK LENGTH AT INBD FLANGE IS 1", OTBD FLANGE IS 0.9", DAMAGED CUTOUT IS 1.5" X 0.75" (2 LOCATIONS), THIS IS CLASSIFLED AS A MAJOR REPAIR WITH AND10134-2007-7075T6511 AS REPAIR ANGLE, REPAIR SIZE IS 2" X 4".