What was found
INSPECTION TYPE:C, MAIN DECK STA 246 FLOORBEAM ATTACH CLIP FOUND CRACKED AT LBL 50" MAIN DECK STA 246 FLOORBEAM AT LBL50" ATT CLIP REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MAIN DECK STA 246 FLOORBEAM ATTACH CLIP FOUND CRACKED AT LBL 50" MAIN DECK STA 246 FLOORBEAM AT LBL50" ATT CLIP REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.