What was found
INSPECTION TYPE:C, MAIN DECK STA 246 FLOORBEAM ATTACH ANGLE FOUND CRACKED AT LBL 25". MAIN DECK STA 246 FLOORBEAM AT LBL 25" ATTACH ANGLE REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, MAIN DECK STA 246 FLOORBEAM ATTACH ANGLE FOUND CRACKED AT LBL 25". MAIN DECK STA 246 FLOORBEAM AT LBL 25" ATTACH ANGLE REPLACED IAW SRM 51-10-02 AND INSTALLED IAW SRM 51-40-02.